The working mechanism is to increase the cleaning effect by cavitation twice or more. When the liquid is put into the cleaner and applied, the ultrasonic wave in the cleaner is a kind of dense, high-frequency wave which radiates and propagates, so that the liquid reciprocating vibration at high speed. In the oscillating negative pressure region, numerous tiny vacuum bubbles are formed because the surrounding liquids can not be replenished. In the positive pressure region, the tiny bubble suddenly closes under pressure. During the closing process, the strong shock wave is produced due to the collision between liquids, which forms an instantaneous high pressure up to several thousand atmospheric pressures and acts on the cleaned one. The workpiece is on the workpiece. The grease and impurities adsorbed on the workpiece rapidly break away from the workpiece under continuous and instantaneous high pressure. So as to achieve the purpose of cleanliness.
1. connect the generator to the cleaning tank.
2. injecting the selected cleaning fluid into the tank.
3. connect generator to 220V + 10%50 Hz AC power supply.
4. turn on the generator power switch, and the power indicator lights up (at this time, the liquid in the tank starts to vibrate and cavitation).
Matters needing attention in ultrasonic cleaning machine:
In order to prolong the service life, it is suggested that the equipment should be placed in the ventilated and dry area, and the fan holes on the rear side of the generator should be cleaned regularly. There are air outlets on the four sides of the generator to make the airflow unobstructed.
(1) Cleaning tank must be put into liquid before starting work, the lowest water level is higher than 100 mm (bottom vibration type) and placed horizontally, when the transducer is on the side, for cleaning tank along 100 mm, such as in the air state to open the opportunity to damage the machine.
(2) When the cleaning cylinder temperature is normal, do not directly inject high-temperature liquid into the cylinder, so as not to cause transducer loose and affect the normal use of the machine.
(3) When the cleaning fluid needs to be replaced due to pollution, do not inject cryogenic liquids directly into the high-temperature cylinder block, which can also lead to transducer shedding, and should close the heater switch, so as not to damage the heater because there is no liquid in the tank.
(4) check the transducer regularly, do not make it become damp and impact, so as not to cause unnecessary loss. After use, the main power supply should be turned off. Do not reboot immediately after shutdown. The interval should be more than 1 minutes.